Server Cabinet Building

We can build your server cabinet to any spec required

Installing devices from UPS’S

Rack mount servers, patch panels

Routers, modems, switches, KVM units

 All done to a high degree of neatness

With over 18 years in the I.T. industry I have had personal experiences with working on equipment in server cabinets and have seen completely unmanageable setups, a badly setup server cabinet could affect Safety, Performance, Manageability and Serviceability.



Safety

UPS’S

We would calculate the total load from all the devices in you cabinet and recommend a UPS unit to suit

Power IN

On small cabinet builds where there’s not much load, then a 13 amp mains socket feeding the UPS would suffice, although we would recommend this to be isolated on its own mains circuit, on larger cabinets with greater load we recommend an isolated 15amp socket for each individual cabinet

Cabinet Stability

Server cabinets can kill people if not setup correctly, an incorrectly setup cabinet with middle to upper weight distribution and without a heavy duty front plinth can easily topple over if a server was to be racked out for maintenance,  it’s not rocket science its careful management and common sense,

Earth

With the ups earthed to the cabinet all of the internal mains cabling will be protected by this, should a live cable touch any of the metal parts then the ups will instantly shut off, At Microhal we recommend only one power source into the cabinet for each UPS installed and all internal device’s to be fed from the UPS,

Performance

Termination and cable management can affect performance of your network, our engineers are very careful when it comes to routing the cable and termination, especially when using the much thicker Cat6 cable with frequencies running up to 200Mhz, any kinking, crushing or elongation of the cable has a proportional effect on impedance and a consequent knock-on effect on transmission performance

Manageability

We can design the layout to suit your needs and the environment you are in, we would recommend to have access to at least the front and back of the cabinet preferably all four sides if you have the space,

Serviceability

For rack mount servers all cabling would be distributed through a cable tray so you can rack out the server with confidence that you are not going to either pull out a cable from the server or snag another cable from another server

 

SERVER CABINET TIDY UP SERVICE

After having a server cabinet for a few years you may find that as devices have been added on over time the cabinet can become unmanageable and a complete rewire of the cabinet is required

 Maybe you have outgrown your server cabinet and you either need a larger cabinet or an additional one

 Whatever the situation we can help

 

At Microhal we pride ourselves on quality of workmanship, Server cabinet building isn’t just throwing a load of hardware together for our engineers the finished product is a piece of artwork and something to be proud of.

 